Skip to content
RenoktaRenokta

Scope 1, 2 and 3 emissions explained: GHG Protocol guide

Scope 1 is direct emissions, Scope 2 comes from purchased energy and Scope 3 from the value chain. The GHG Protocol uses these three scopes as the common language of a carbon inventory.

Request a demo

Renokta Ekibi ·

An offshore wind farm generating renewable energy at sea.
Separating the three scopes
BoundarydecisionScope 1Scope 2Scope 3Combinedreport
  1. 1. Boundary decisionDecide which sites and activities enter the inventory.
  2. 2. Scope 1Fuel combustion, company vehicles and refrigerant leaks are calculated directly.
  3. 3. Scope 2Purchased electricity and heat are treated location-based and market-based.
  4. 4. Scope 3Meaningful value chain categories are added step by step.
  5. 5. Combined reportScopes are shown separately and total CO₂e is reported.

The GHG Protocol divides corporate emissions into three scopes. Scope 1 covers direct emissions from sources the organization owns or controls. Scope 2 covers indirect emissions from producing the electricity, heat and steam it buys. Scope 3 includes all other indirect emissions in the value chain.

What are Scope 1 emissions?

Scope 1 emissions are released directly from sources under the organization's own control. Because the source sits in your facility or vehicle, this is usually the easiest scope to collect data for.

  • Burning natural gas, fuel oil or other fuels in boilers, furnaces and generators.
  • Fuel use of vehicles the company owns, or leases and operates.
  • Refrigerant gases that leak from cooling and air conditioning systems.
  • Non-combustion process emissions from the production process itself.

What are Scope 2 emissions?

Scope 2 emissions occur where the electricity, heat, steam or cooling that an organization buys is produced. The emission happens at the power plant, but it belongs in your inventory because your consumption creates the demand.

For most organizations, electricity is the largest Scope 2 item. That makes meter data decisive here: the more detailed the measurement, the clearer it becomes which site, shift or machine accounts for a high share.

How is the boundary drawn: operational control or equity share?

Which sites count as Scope 1 and 2 depends on the consolidation approach chosen. Under operational control, all sites the organization operates are included; under equity share, only the share of ownership is.

What is the difference between location-based and market-based?

The GHG Protocol recommends reporting Scope 2 with two approaches side by side. The location-based method uses the average emission intensity of the grid where consumption happens. The market-based method reflects the electricity products the organization actually chose, such as contractual renewable energy certificates.

The two methods can give different results; the gap is not an error, because each approach answers a different question. Which emission factors and certificates to use should be decided from current official sources.

What are Scope 3 emissions?

Scope 3 emissions arise from an organization's activities but come from sources it neither owns nor controls. They span both the upstream supply chain and the product's life after sale.

  • Production of purchased goods and services.
  • Supplier and customer transport, business travel and employee commuting.
  • Waste disposal.
  • Use of sold products and their treatment at end of life.

Scope 3 is the largest share for many organizations, yet the hardest to collect data for, because the data comes from suppliers or estimates. It is therefore healthier to set up Scopes 1 and 2 solidly first, then add meaningful Scope 3 categories step by step.

How is Scope 3 divided into categories?

The GHG Protocol Scope 3 Standard splits the value chain into fifteen categories. Purchased goods and services, capital goods, fuel- and energy-related activities, transport, waste, business travel, employee commuting, leased assets, use of sold products and investments are some of them.

Not every category is meaningful for every organization. The relevant ones are selected by size and sector, and the reasons for excluding others are recorded.

Which scopes does a measurement infrastructure support?

Meter and sensor data contributes most directly to Scope 1 and Scope 2. Electricity meters feed Scope 2, while natural gas and fuel meters and vehicle distance data feed Scope 1. Scope 3 usually needs additional data sources.

In short, separating the three scopes correctly is the basis of a credible inventory. For measurement and reporting by scope, our carbon footprint monitoring solution and a needs discovery call can help us review your existing data sources together.

Frequently asked questions

What is the main difference between Scope 1, 2 and 3?
Scope 1 is direct emissions from sources the organization controls. Scope 2 is indirect emissions from purchased energy, and Scope 3 covers other indirect emissions in the value chain.
Which scope does electricity use fall under?
Purchased electricity falls under Scope 2. The emission occurs at the power plant, but it is included in your inventory because your consumption creates the demand.
What are location-based and market-based Scope 2?
The location-based method uses the grid average. The market-based method reflects the electricity products the organization chose. The GHG Protocol recommends reporting both together.
Is Scope 3 mandatory to calculate?
It depends on the standard applied, legislation and customer requests. Check current official texts; most organizations set up Scope 1 and 2 first.
Which scope do company vehicles belong to?
Fuel use of vehicles the company owns or controls is Scope 1. Business travel in an employee's own car usually falls under Scope 3.

Let's plan the right solution for you, together.

Request a demo