Skip to content
RenoktaRenokta

People counting systems

Counts entries and exits, shows live occupancy and reports on it.

Request a demo
Ticket gates with digital displays and passengers passing through at a train station.

Measured point

People inside

Renokta IoT Platform · People counting

Live · --:--:--

Sample store › Entrances

  • People inside

    75kişi

  • Entries today

    1,222kişi

  • Occupancy

    68%

  • Average stay

    16dk

People inside

TodayLast week75 kişi

Capacity 110

Entries by door

  • Main entrance57 kişi/sa
  • Car park door29 kişi/sa
  • Arcade link37 kişi/sa
  • Staff door10 kişi/sa

Event feed

  • 0Critical
  • 1Major
  • 1Minor
  • 2Warning
  • Occupancy is approaching the 80% thresholdOpen
  • Sudden rush at the main entranceOpen
  • Staff door sensor battery is lowOpen

Sample screen. Values are simulated.

What is a people counting system?

A people counting system uses sensors to count the people passing through a door or an area, and produces entries, exits and live occupancy. The result appears on a dashboard and becomes hourly or daily reports. It is used in shops, offices, exhibitions and public spaces to measure footfall and keep an eye on capacity.

How does it work?

The sensor is mounted above or beside the entrance. It counts each passage together with its direction and sends the count through a gateway to the platform, which subtracts exits from entries to get live occupancy.

  • Sensor: detects the person and the direction.
  • Gateway or network link: carries the count to the platform.
  • Platform: calculates totals, occupancy and hourly distribution.
  • Output: dashboard, report, capacity alert or display.

Which quantities are measured?

  • Entries and exits: to see visitor traffic.
  • Live occupancy: to track how close you are to the capacity limit.
  • Hourly and daily distribution: to find peak hours and plan staffing.
  • Zone comparison: to see the difference in load between doors or floors.

Which method or technology should you choose?

  • Infrared beam: counts when the light path is broken; simple and low cost, but people walking side by side may be counted as one.
  • ToF (time of flight) or depth sensor: measures distance to detect passage and direction; it can work without recording images, though placement must be planned on wide doors.
  • Stereo camera: derives depth from two lenses and can separate people in tight passages; whether the camera processes the image on the device and does not store it should be settled in the configuration.
  • Thermal sensor: picks out a person by heat difference and produces no picture; ambient temperature and very close passages can limit it.
  • Video analytics: counts from existing camera footage and may need no extra hardware; because images are processed, it needs more careful handling from a data protection view.

Who is it for?

  • Shops and shopping centres: footfall and staff planning.
  • Offices and coworking spaces: occupancy and space use.
  • Museums, exhibitions and event venues: capacity control.
  • Libraries, gyms and schools: seeing peak hours.
  • Transit stops and stations: passage density.

How do alarms and notifications work?

A limit is set for occupancy. When the count nears or passes it, the platform notifies the right people. The same information can show on an entrance display as available or full. Alerts are logged and show in the report.

If the link to a sensor drops, the platform reports it as a device alert. Whether passages during the outage are still counted depends on the sensor model, so this should be checked when selecting it.

Integration with existing systems

Counts can pass through an API or MQTT to building management, sales software, visitor displays or reporting. For field protocols and in-house software, adaptation follows the need. The scope is set during the survey.

Data privacy and security

People counting should be designed to produce numbers, not identities. Methods that store no images, such as infrared, ToF and thermal, have an advantage here; with camera-based methods, how images are processed and stored needs separate attention. Access is limited by role.

A GDPR or KVKK assessment is made with your own privacy notice and legal adviser; this page is not legal advice.

Installation process and what a quote needs

First the entrances are walked through on site, checking door width, ceiling height and lighting. A pilot runs on one or two entrances, the count is compared with a manual count, and then the remaining entrances follow.

For a quote, the number of entrances, door widths, ceiling height, preferred method and existing software are enough. Contact us with these details and we will plan the survey together.

Highlights

  • Entries, exits and live occupancy

    Passages are counted with direction, and live occupancy is shown by subtracting exits from entries.

  • Methods that store no images

    Infrared, ToF and thermal methods produce counts without the need to record images.

  • Capacity threshold alerts

    When occupancy nears the set limit, the right people are notified and a display can show it.

  • Hourly and daily reports

    Peak hours and daily distribution are reported, so staffing and space can be planned with this data.

  • Totals across several entrances

    Counts from multiple doors are gathered on one platform and the doors can be compared.

From the door to the report: people counting

Sensors at the doors count entries and exits. The platform works out how many people are inside, warns at the occupancy limit and prepares the report.

Main entrancesensorCar parkdoorArcade linkStaff doorLoRaWANgatewayRenokta IoTplatformOccupancyalertVisitorreportStaffnotice

A busy afternoon

  1. Door sensors count every entry and exit and pass the data to the gateway.
  2. The platform keeps the headcount current from the difference between entries and exits.
  3. When occupancy nears the 80% threshold, the manager is notified.
  4. The team opens an extra till, and an hourly traffic report is ready at the end of the day.

The diagram shows the logic; names are examples.

Frequently asked questions

How does a people counting system work?
A sensor at the door counts each person and direction and sends the count to the platform, which calculates live occupancy from entries and exits and builds reports.
Which sensor type should be chosen?
It depends on door width, lighting and privacy expectations. Infrared, ToF, stereo, thermal and video analytics are compared during the survey to find the right fit.
Can people be counted without a camera?
Yes; infrared beam, ToF and thermal sensors can count without recording images. Their limits are assessed during the survey, depending on the door layout.
What determines the cost?
The number of entrances, door width, chosen technology, communication method and integration scope determine the cost. Exact details follow the survey.
Does it work with our software or displays?
Counts can pass through an API or MQTT to building management, sales software or displays. The scope is adapted to your needs.
Who owns the data, and what about GDPR or KVKK?
The data belongs to the organisation, and access is limited by role. A GDPR or KVKK assessment should be made with your own privacy notice and legal adviser.
How long does installation take?
It varies with the number of entrances and door layout, and becomes clear during the survey. Usually a pilot on one or two entrances comes first.
How is counting accuracy checked?
During the pilot, the sensor count is compared with a manual count and the position is adjusted if needed. Accuracy varies with the door layout and the method.

Our solutions

Let's plan the right solution for you, together.

Request a demo