Skip to content
RenoktaRenokta

Energy management

Control over consumption and production, with detailed reporting.

Request a demo
Electric vehicle chargers and energy cabinets under a solar canopy.

Measured point

Building power profile

Renokta IoT Platform · Energy management

Live · --:--:--

Sample building › Power and consumption

  • Current power

    282kW

  • Consumption today

    3,362kWh

  • Monthly target used

    61%

  • Standby load

    47kW

Building power profile

TodayYesterday282 kW

Power target 360

Power by usage group

  • Production line132 kW
  • Heating and cooling80 kW
  • Lighting30 kW
  • Office sockets24 kW
  • IT room16 kW

Event feed

  • 0Critical
  • 0Major
  • 1Minor
  • 3Warning
  • Power is approaching the 360 kW targetOpen
  • Out-of-hours draw on the office socket groupOpen
  • Heating schedule switched to weekend modeOpen

Sample screen. Values are simulated.

What is energy management?

Energy management is a metering and monitoring practice that measures the electricity use of a building or plant by usage group with sub-meters, current sensors and smart plugs, compares use with a target, manages it with schedules and produces regular reports. It also gives a measurement base for energy management system work such as ISO 50001.

How does it work?

Sensors placed on the main panel and sub-groups measure power, and a gateway sends the data to the platform. The platform gathers usage groups and the target in one place.

  • A main panel current sensor, smart plugs and thermostats produce data.
  • A gateway carries the data to the platform.
  • The platform compares power with the target and runs schedule rules.
  • A warning is sent as the target nears; a monthly report is produced.

Usage groups are defined up front; adding a new group extends existing measurements and reports without breaking them. The report shows the target and the actual in the same table.

What quantities are measured?

  • Current power and daily consumption: the basic monitoring data.
  • Power by usage group: shows the split between production, heating and cooling, lighting, office and IT.
  • Standby load: reveals what stays on outside working hours.
  • Monthly target used: shows how close you are to the target.
  • Thermostat and schedule status: tracks whether heating and cooling schedules are applied.

Which method or technology should you choose?

  • Sub-meter (Modbus or pulse output): gives detailed, dependable readings; installation needs work inside the panel.
  • Clamp-on current sensor: quick to fit without opening the panel; it does not measure voltage, so power is calculated from assumed values.
  • Smart plug: monitors and can switch single devices and office sockets; covers only loads plugged into it.
  • Smart thermostat: manages heating and cooling schedules; comfort needs should be considered separately.

Who is it for?

  • Factories and plants with many usage groups
  • Office buildings and business centres
  • Store chains and multi-branch businesses
  • Organisations building a metering base for ISO 50001 work
  • Managers who want consumption split by usage group

How do alarms and notifications work?

When power nears the target, or consumption outside working hours is higher than expected, the platform raises a warning. It goes to chosen channels such as e-mail or message, and is acknowledged and recorded.

If a link drops, the point is flagged as missing data. Gateways that keep a local buffer can send the data once the link returns; this depends on the device and configuration.

Integration with existing systems

Data from existing meters, analysers, building management systems or SCADA can be taken in over Modbus, MQTT or an API. Reports can be passed to other systems. Integration is adapted to the need, with scope settled during the survey.

Data privacy and security

The system collects consumption and device status and is not meant to track individuals. Users are authorised by role. ISO 50001 conformity is not an automatic result of this solution. Data protection and compliance assessments are handled with the company own privacy notice and advisers.

Installation process and what a quote needs

A survey lists the main panel, sub-panels and usage groups. In a pilot a few groups are measured and the target and report are set up; then other groups follow.

For a quote, share the number of usage groups, the building or plant area, existing meters and the report type you want through the contact form.

For live control, see energy SCADA and automation; for catching deviations in consumption, see energy analysis and anomaly detection.

Highlights

  • Power split by usage group

    Groups such as production, climate control, lighting and office are measured and compared separately.

  • Power target tracking

    A power or monthly consumption target is set and a warning is sent as it nears.

  • Standby load detection

    Sockets and devices left on outside working hours become visible.

  • Schedule rules

    Smart plugs and thermostats are moved to night and weekend mode by timed rules.

  • Monthly energy report

    Per-group consumption, the target and events are collected in a regular report.

  • Measurement base for ISO 50001 work

    Measured data gives a record base that can support energy management system work.

Usage to target: energy management

Current sensors, smart plugs and thermostats watch the usage groups. The platform compares power with the target, manages schedules and reports.

Main panelCT sensorSmart plugLightingcontrolSmartthermostatLoRaWANgatewayRenokta IoTplatformTargetalertScheduleruleMonthlyreport

Standby load after hours

  1. Smart plugs and current sensors measure the power of each usage group.
  2. After working hours the office socket group stays above the expected standby level, and the platform raises a warning.
  3. A schedule rule switches off the smart plugs in that group and sets the thermostats to night mode.
  4. At day end, per-group consumption appears in the monthly report alongside the target.

The diagram shows the logic; names are examples.

Frequently asked questions

How does an energy management system work?
Sub-meters, current sensors and smart plugs measure usage groups and a gateway sends the data to the platform. The platform compares power with the target, manages schedules and reports.
Which sensors and meters are used?
Sub-meters, clamp-on current sensors, smart plugs and smart thermostats are used. The choice depends on usage groups and panel access and is made during the survey.
What determines the cost?
The number of usage groups and points, the communication method, whether existing meters can be reused and the scope of integration set the cost. The detail follows the survey.
Is it compatible with my existing meters and systems?
Data from meters and systems that offer Modbus, MQTT or an API can be taken in. Fit depends on the device model, is adapted to the need and is checked in the survey.
Can it be used for ISO 50001?
The measured data can serve as a base for an energy management system built on this standard. The system itself does not provide conformity; your organisation runs certification.
Who owns the data and how is privacy handled?
The measured consumption data belongs to the customer, and access is limited by role. Data protection and retention are handled with the company own privacy notice and legal counsel.
How long does installation take?
It varies with the number of usage groups and points and with panel access, and is settled in the survey. Pilots that start with clamp-on sensors are usually quicker to commission.

Our solutions

Let's plan the right solution for you, together.

Request a demo